Glacier Coolant Description of LM-16C Glacier Coolant Product
Main parameters
Glacier Coolant LM-16C is mainly suitable for high temperature environment. As a heat transfer fluid, the operation temperature of LM-16C is -30°C~340°C. Glacier Coolant LM-16C has good thermal stability and good vapor pressure due to its stable structure. Glacier Coolant LM-16C is recommended to use in closed cycle system. The closed-cup flash point and boiling point of Glacier Coolant LM-16C are 128 °C and 272 °C, respectively.
Physical parameters (reference value)
|
Temperature (°C) |
-30 |
-20 |
20 |
50 |
100 |
200 |
300 |
340 |
|
Density (g/cm3) |
1.040 |
1.034 |
1.002 |
0.985 |
0.947 |
0.872 |
0.797 |
0.767 |
|
Dynamic viscosity (cP) |
71.35 |
32.72 |
5.75 |
2.64 |
1.25 |
0.38 |
0.18 |
0.15 |
|
Thermal conductivity (W/m·K) |
0.1330 |
0.1326 |
0.1306 |
0.1314 |
0.1244 |
0.1105 |
0.0954 |
0.0884 |
|
Specific heat (kJ/kg·K) |
1.5379 |
1.5564 |
1.6280 |
1.7054 |
1.8422 |
1.9269 |
2.4308 |
2.6573 |
Product Features
The product has the following features:
◈ Good low-temperature performance, wide range of temperatures, heating and coolant system at -30~340 °C can be carried out with the same heat carrier.
◈ Good thermal stability, not easy to produce coking and carbon.
◈ Almost non-corrosive to metal, no adverse effect on the operator.
Non-metallic compatibility
The compatibility of Glacier Coolant LM-16C with non-metallic materials is as follows:
|
Material |
Silicone rubber |
Viton |
PP |
PTFE |
HDPE |
Polyethylene |
|
LM-16C |
× |
√ |
√ |
√ |
√ |
√ |
Note: "√" means that there is no dissolution, swelling, aging and other phenomena. For compatibility with other materials, please consult a technician.
Usage Method
1. LM-16C can be used alone, and cannot be mixed with other coolants and heat transfer fluids.
2. After confirming that there is no leakage point in the system, clean the system and add Glacier Coolant solution to the system as soon as possible after drying.
3. It is only used in a closed system. Prevent moisture from entering the system during use.
4. It shall not be directly used to heat or cool chemicals with oxidizing effect. When used for indirect heating in the production process of food or drugs, it should meet the requirements of relevant national food and drug safety standards.
After-sale service and testing items
Relevant personnel will provide tracking service during the using process of the product. They will regularly sample the products used by the customers and take them back to the company for testing. The testing items rely on the company's low-temperature liquid heat transfer medium engineering laboratory. The test report will be feed back to the customer timely. Solutions and cooperation with relevant technical services in case of problems will be provided. The 360 degree all-round after-sales service will be provided to the customers.
Inspection cycle
When used for the first time, the product should be inspected within 3 months after the product is injected into the system and completed commissioning, and then at least once a year, the inspection items are appearance, closed flash point, viscosity, acid number and other indicators.
Notes
For the specific requirements and safety precautions for the operation, use and storage of Glacier Coolant, see the safety technical manual, safety label, enterprise standard and other information of the product. Please read carefully before using this type of product.